Products Order Form Bibliography Flow Tech Inc.

 

MICROFIL® Silicone Rubber Injection Compounds

MICROFIL® CP-101 For Cast Corrosion Preparations

 

Product Description

MICROFIL® Silicone Rubber Injection Compounds

Prices And Available Colors

Kit        Weight            Specification                Price

B            1 lb.                One Color                    $125.00

C            2 lbs.              One or two colors          $225.00

D            1 gal. (8 lbs.)   One to four colors         $780.00

Kit weight is based upon the combined weight of MV-Compound and MV-Diluent only, ie. a 1lb. kit contains 8 oz. of MV compound and 8 oz. of diluent. Sufficient MV-Curing Agent is supplied at no charge to cure the contents of the kit. A one pound kit has a volume of approximately 400 ml.

Available Colors

MV-112        White            (Radiopaque)

MV-117        Orange          (Radiopaque)

MV-120        Blue              (Radiopaque)

MV-122        Yellow           (Radiopaque)

MV-130        Red               (Radiopaque)

MV-132        Clear

 

MICROFIL® CP-101 For Cast Corrosion Preparations

Kit            Weight            Color                Price

CP-101        1 lb.              Milky White        $115.00

Kit weight is based upon the weight of MICROFIL® CP-101 (16 oz.). Sufficient curing agents are supplied at no charge to cure the contents of the kit.

Curing System:  Stannous octoate in combination with ethyl silicate.
Mixing Directions:    Cure is accomplished by mixing CP-101 with 5% ethyl silicate and 5% stannous octoate (by weight). Upon addition of curing agents, working time is approximately 45 minutes.
Clearing Procedure: Either alcohol-methyl salicylate or glycerin may be employed. Kindly refer to MICROFIL page for details.
Corrosion Preparations: Potassium hydroxide may be used in studies where the vessels have a diameter of greater than 100 microns.
Corrosion Clearing Procedure: Cast corrosion can be obtained as follows: After the casting material has been completely hardened, place the perfused organ in 20% potassium hydroxide or sodium hydroxide solution for several days. The cast should then be rinsed several times in water until all the tissue is removed. The casting time depends both on the concentration of the corrosive solution and on the tissue itself. Lung and heart tissue require 5-6 days in potassium hydroxide whereas bone and brain tissue may require 35% potassium hydroxide for up to 10 days.
Advantages: MICROFIL CP-101 will maintain dimensional integrity on storage. There is no diluent in the system.

Prices are subject to change without notice.           

For "Terms" and instructions for "International Orders" see Order Form.

         

Click here to order now

 

Copyright © 1999 Flow Tech, Inc.
MICROFIL® is a registered trademark of Flow Tech, Inc., Carver, Massachusetts