MICROFILâ compounds will fill and opacify microvascular and other spaces of non-surviving animals and post-mortem tissue under physiological injection pressure. The continuous, closed vascular system lends itself to flow through injection or perfusion techniques. Following injection, MICROFIL compounds cure to form a three-dimensional cast of the vasculature.
MICROFIL® MV-series compounds are available in five radiopaque colors, as
well as clear. MV-series
compounds require either an alcohol-methyl salicylate or glycerin clearing
sequence, whereby the refractive index of the clearing solution is the same as
the refractive index of the tissue. This
allows for microscopic examination of a selected vascular bed. MICROFIL®
CP-101 compound is intended for use in cast-corrosion techniques, and is
designed for filling large blood vessels (greater than 100 microns).
Although the CP-101 compound will fill capillaries, these vessels
fragment when the supporting tissue is removed through exposure to a potassium
hydroxide solution. When cured, MICROFIL® CP-101 is a milky white in color.
Casts made using CP-101 will maintain their dimensional accuracy
indefinitely. Advantages
offered with MICROFIL® compounds over previously available rubber injection
materials include: Complete
filling with minimal shrinkage, to enhance vessel continuity and to produce in
cleared preparations a vivid, optically cleared specimen that allows a precise
study of the microcirculation. Color
diversity, to provide delineation within the circulatory tree for microscopic
examination and photographic illustration, Areas of investigationIn
physiology, MICROFIL® visualization provides a means for establishing the
precise vascular architecture of specific organs, allowing comparison between
normal and abnormal structure. In
surgery, visualization of the microcirculation and microanatomy is leading to
improved surgical techniques in the repair of nerves, tendons, and blood
vessels. In
gastrointestinal research, MICROFIL® compounds characterize and describe
changes in vascular patterns associated with several pathological conditions. Injected
specimens, when preserved in methyl salicylate or glycerin, also serve as a
definitive teaching adjunct. MV-series mixing procedureTo
achieve a viscosity level suitable for injection of the microcirculation, it
is necessary to blend the MV compound with an equal quantity (by weight) of
MV-Diluent. Volume mixing
requires 5ml of diluent for every 4ml of compound.
The mixture of compound and diluent is catalyzed with 5% (by weight or
volume) of MV Curing Agent. Viscosity
ranges from 20 to 30 centipoise. Working
time is 20 minutes and begins with the addition of curing agent. Table 1Physical
properties of MICROFIL® compound
Notes; Catalyzed
mixtures will form an elastomeric gel after 90 minutes at room temperature.
Curing takes place with non-exothermic cross-linking and minimal volume
change. It
has been possible to refrigerate specimens immediately after injection and
still obtain complete cure after overnight aging. The procedure decreases odor level for subsequent sectioning. Perfusion techniquesTwo
techniques of tissue clearing are described below. Alcohol-methyl salicylate clearing produces a stiffer tissue,
which, from an aesthetic point, provides a pleasing view for gross
observation. Glycerin clearing
produces a more flexible tissue, allowing easier manipulation for a given
vessel. Alcohol-methyl
salicylate clearing Non-wetting
features of MICROFIL® compounds prevent any interaction with blood.
Therefore, in the non-surviving animal, a selected vascular bed can be
readily perfused without prior washout of blood.
Heparinization to maintain blood fluidity, however, has been used to
realize improved injection preparations. For
the injection of blood vessels from vascular beds removed post-mortem, washout
of clotted blood with saline is advisable. Selected
vascular beds are perfused through their accessible artery and drained through
a similar vein. Infusion
pressures will vary with the animal’s mean systemic pressure.
For organs from the dog, cat, rat, and
man, a pressure of 150mm.Hg for arterial filling has been used, and 25 to
50mm.Hg for venous fillings.
Table
2
Alcohol-methyl salicylate clearing sequence
If tissue has not cleared, return to 95% ethyl alcohol stage and repeat final
steps of clearing procedure. Notes After
the vascular bed is perfused and the MICROFIL® injection mass allowed to cure
overnight at room temperature, the tissue is subjected to the clearing
sequence described in Table 2. Thin
tissues may be cleared without sectioning, but thicker organs, such as kidney
or brain, should be cut into 1-centimeter slices before immersion.
The alcohol-methyl salicylate clearing technique is applicable to all
types of tissue with the exception of brain tissue.
In the case of brain tissues, it is necessary to allow two days for
each step, with an alcohol solution change every day.
Glycerine clearing
The
animal is anesthetized with Nembutal, 25 mg/Kg i.v., at the same time is is
heparinized, to ensure effective removal of its blood volume during perfusion. A
midline incision exposes the abdominal viscera from the sternal notch to
symphysis. Following the
placement of an abdominal retractor, the thoracic cage is opened rapidly, the
thoracic aorta isolated, and a polyethylene cannula inserted distally.
The arterial cannula is connected to a sine wave perfusion pump and,
prior to instigating perfusion, the right atrium is opened to serve as a drain
vent. The
animal is perfused with saline until all of the visceral blood volume is
flushed out and the perfusate drained through the arterial vent is essentially
free of blood. Adequate perfusion is characterized by severe blanching of all
visceral organs. During
perfusion, the curing agent is added to the MICROFIL® injection mass.
When perfusion is complete, the silicone rubber (e.g., MV-130 Red) is
infused through the aortic cannula by syringe.
When filling is complete, all organs have a rich, red coloration.
MICROFIL® compound infusion is continued until the injection mass
flows freely from the atrial vent. The
atrium and arterial cannula are then clamped and the animal is placed under
refrigeration at 4 degrees C overnight, to allow polymerization. On the following day, specimens are taken by careful dissection, and placed in a 50% mixture of water and glycerin. At successive 24-hour intervals, the glycerin concentration is raised to 75%, then 85%, and finally pure glycerin. This procedure clears the tissue so that microscopic examination readily allows three-dimensional visualization of the vascular bed.
Additional Notes
1.
All MV-series
compounds are compatible with one another. Therefore, it is possible to mix colors together to suit your
needs (e.g., mix MV-120 Blue with MV-122 Yellow to produce a green compound).
2.
Faster cure rates are
possible by replacing the conventional MV Curing Agent with 2% ethyl silicate
and 1% stannous octoate. Using
this cross-link and curing agent combination decreases working time to 5
minutes with complete cure in 20 minutes. If you desire this type of cure system, please specify when
placing your order. There is no
extra charge for substituting this cure system in place of MV Curing Agent.
3.
Occasionally it may
be necessary to decrease viscosity by changing the mix ratio to either 2 or 3
parts MV-Diluent for each part MV compound. If your study requires such action, the correct level of MV
Curing Agent is 10% (by weight) of the amount of MV compound used.
4.
One procedure for
vessel differentiation is to completely fill a given circulation with
conventional MV compound (e.g., MV-130 Red) then, once the circulation is
filled, immediately re-inject the artery with a high-viscosity version of MV
compound in a different color (e.g., MV-120 Blue). This is accomplished by substituting MV-Diluent, which has a
viscosity of 5cps, with HV-Diluent, which has a viscosity of 1000 cps.
With HV-Diluent, the viscosity of MV-130 Red increased to 350-450 cps.
Although this procedure stopped penetration at the capillary level,
complete success was obscured by shunting activity.
If you desire to replace MV-Diluent with HV-Diluent, please specify
when placing your order. There is
no extra charge for this substitution.
5.
Store MICROFIL® kits
at room temperature for maximum retention of pigment dispersion.
Keep all containers tightly capped.
If pigment settling occurs, it is better to lightly shake the MICROFIL®
compound container and decant this portion.
Stirring the container may put an agglomerated pigment particle into
the system, which can be detrimental to perfusion. 6. If catalyzed material should spill on clothing, the best available solvent is MV-Diluent. To facilitate removal of cured compound, swelling and softening will occur on contact with an aromatic solvent such as toluene or xylene, or chlorinated solvents such as trichloroethylene.
While the information herein is believed to be reliable, Flow Tech does not guarantee its accuracy. Users are urged to perform their own tests. MICROFIL® products are sold without warranty, and various patents may be pertinent to their use and to the use of compositions containing them. The information contained herein is not intended as a recommendation to use MICROFIL® products so as to infringe on any patent. Flow Tech assumes no liability for the user’s violation of patent or other rights.
|
|